TEAM Climate Monitoring Protocol 3.0
26
Collection of test data: Once the sensors are all connected, turn the data logger back on and
wait for about 1-2 hours for data collection. Slowly add 1/3 of a liter of water (about 10 mm) to
the rain gauge over a 5-10 minute period.
5.1.4 Extract the data from the data logger
Examine the data collected to ensure the sensors and data logger are working properly. Select the
Collect Data tab in the main PC200W window and press the Change Table’s Output File
button to specify the name of the file and directory where the data will be written. Finally, press
the Collect button on the upper left corner of the tab to write the data to the file (Figure 9).
Figure 9. Collect Data tab in the main PC200W window.
Examine the data: Open the file in a text editor or Excel and examine the values. The values for
the duplicate Temperature/RH and solar radiation sensors should show as “NA”, but the rest of
the values should show reasonable figures for the sensors.
5.1.5 Set up a dedicated data logger for the radiation sensor (Level 3)
TO BE WRITTEN.
5.2 Installing the base tower
This section describes briefly the installation and proper grounding of the base tower (UT10) that
will house all the equipment for the climate station. More detailed instructions can be found in
the manual of the base tower (http://www.campbellsci.com/documents/manuals/ut10.pdf).